Harshaw TLD 5500 Thermoluminescence Dosimetry system

The Thermo Scientiffc™ Harshaw™ 5500 TLD Reader is an automated, high capacity hot-gas TLD reader designed for processing un-mounted dosimeters. Ideal for higher volume applications in medical physics, health physics, material research, and industrial applications, the Harshaw 5500 can automatically process up to 50 dosimeters per reading session, to efffciently deliver accurate results with reduced manpower.  Compact, attractive reader has a linear, programmable heating system and a cooled photomultiplier tube with associated electronics to measure the TL light output. The WinREMS Software, which runs on a separate computer, provides the user interface, the reader control and the applications software.

Key Features Technical Specifications Applications

l   Easy operation, service and maintenance

l   Measurement quality assurance

l   Unattended automatic operation for up to 50 dosimeters

l   Thermoelectric PMT cooler for maximum gain stability

l   Unattended automatic background subtraction capability

l   Multiple, programmable, linear time-temperature profiles; heating profile includes pre-heat, acquire and anneal cycles

l   Linear contactless hot gas heating with temperature capability up to 600°C (1112°F)

l   Seven decade dynamic acquisition ranges

l   30 sec. cycle time per chip with normal TTP

l   Withstands 20mm drop on to concrete surface

l   Maintains specifications while exposed to light up to 1000 lux with cover in place

l   Options include glow curve deconvolution software, neutral density filters, and calibration software


Dosimetry Performance When Using LiF:Mg,Ti Chips (TLD-100):

l   Tissue equivalence: Nearly tissue equivalent

l   Batch uniformity: ±15% standard deviation from the batch mean, tighter on special request

l   Residual TL signal: <0.2% of reading, over the range, without annealing

l   Reuse: more than 500 per dosimeter with <10% sensitivity charge

l   Threshold: <10 µGy (1 mrad) based on 2.26 standard deviation of 10 repeat readings of an unexposed dosimeter

Light Detection System:

l   Dynamic range: 7 decades

l   Warmup time: 30 min.

l   Linearity: <1% deviation

l   Stability: <1.0 mGy standard deviation of 10 consecutive readings

l   Dark current: <50 mGy 137Cs equivalent

l   Test light: temperature-stabilized LED

l   Stability: <0.5% standard deviation of 10 consecutive readings

l   Color: blue (wavelength 470 nm)

Dosimeter Heating System:

l   Method: linear hot nitrogen gas

l   Time/Temperature Profile (TTP) temperature reproducibility: (±1°C)

Clinical/Research Dosimetry

l   Total body irradiation dose verification

l   Skin irradiation dose verification

l   Critical organ dose verification

l   Radiotherapy planning verification

l   CT dose measurement

l   Diagnostic dose studies

l   Stereotactic beam output factor measurement

Industrial

l   Radiation hardening studies

l   Environmental studies